Evolution 2
Next generation of single-patient use devices that provide patients with intermittent, sequential compression therapy to prevent DVT
Select the Cooling Capacity to view Available Models and Specifications
240 WATTS
Model # | RC15A250 | RC22A250 | ||
---|---|---|---|---|
20R0-FSC | 20R0-XSC | 20R0-FSC | 50R0-FSC | |
Cooling Capacity (0°C DeltaT) | 240 Watts | 240 Watts | 240 Watts | 240 Watts |
Chassis Depth | 15" Deep | 22" Deep | 22" Deep | 22" Deep |
Pump Pressure (Max) | 1.0 bar (15psi) | 1.0 bar (15psi) | 1.0 bar (15psi) | 3.0 bar (43.5psi) |
Pump Max Flow Rate | 3.8 LPM | 3.8 LPM | 3.8 LPM | 4.0 LPM |
Pump Type | Centrifugal (Fixed Drive) | Centrifugal (Fixed Drive) | Centrifugal (Fixed Drive) | Gear (Variable Drive) |
Flow Meter | Yes | No | Yes | Yes |
Remote Temp Sensing | Yes | No | Yes | Yes |
Fan Speed Control | Yes | Yes | Yes | Yes |
Electrical Interlock | Yes | No | Yes | Yes |
Max Input Power | 633 Watts | 633 Watts | 633 Watts | 633 Watts |
Dimensions (Inches) | 19 x 5.25 x 15 inches | 19 x 5.25 x 15 inches | 19 x 5.25 x 15 inches | 19 x 5.25 x 15 inches |
Weight | 32 lbs (15 kg) | 32 lbs (15 kg) | 32 lbs (15 kg) | 32 lbs (15 kg) |
Thermal Capacity Performance Curves RC15A250 and RC22A250
Set Temperature minus Ambient Temp (Delta T)
485 WATTS
Model # | RC22A500 | ||
---|---|---|---|
20R0-XSC | 20R0-FSC | 50R0-FSC | |
Cooling Capacity (0°C DeltaT) | 485 Watts | 485 Watts | 485 Watts |
Chassis Depth | 22" Deep | 22" Deep | 22" Deep |
Pump Pressure (Max) | 1.0 bar (15psi) | 1.0 bar (15psi) | 3.0 bar (43.5psi) |
Pump Max Flow Rate | 3.8 LPM | 3.8 LPM | 4.0 LPM |
Pump Type | Centrifugal (Fixed Drive) | Centrifugal (Fixed Drive) | Gear (Variable Drive) |
Flow Meter | No | Yes | Yes |
Remote Temp Sensing | No | Yes | Yes |
Fan Speed Control | Yes | Yes | Yes |
Electrical Interlock | No | Yes | Yes |
Max Input Power | 1223 Watts | 1223 Watts | 1223 Watts |
Dimensions (Inches) | 19 x 5.25 x 22 | 19 x 5.25 x 22 | 19 x 5.25 x 22 |
Weight | 44 lbs (20 kg) | 44 lbs (20 kg) | 44 lbs (20 kg) |
700 WATTS
Model # | RC22A750 | ||
---|---|---|---|
20R0-XSC | 20R0-FSC | 50R0-FSC | |
Cooling Capacity (0°C DeltaT) | 700 Watts | 700 Watts | 700 Watts |
Chassis Depth | 22" Deep | 22" Deep | 22" Deep |
Pump Pressure (Max) | 1.0 bar (15psi) | 1.0 bar (15psi) | 3.0 bar (43.5psi) |
Pump Max Flow Rate | 3.8 LPM | 3.8 LPM | 4.0 LPM |
Pump Type | Centrifugal (Fixed Drive) | Centrifugal (Fixed Drive) | Centrifugal (Fixed Drive) |
Flow Meter | No | Yes | Yes |
Remote Temp Sensing | No | Yes | Yes |
Fan Speed Control | Yes | Yes | Yes |
Electrical Interlock | No | Yes | Yes |
Max Input Power | 1353 Watts | 1353 Watts | 1353 Watts |
Dimensions (Inches) | 19 x 5.25 x 22 | 19 x 5.25 x 22 | 19 x 5.25 x 22 |
Weight | 50.6 lbs (23 kg) | 50.6 lbs (23 kg) | 50.6 lbs (23 kg) |
3U Rack Chiller Gear Pump Performance
Pressure (PSI)
Product Specifications
Mating quick disconnect male fittings for use with 3/8” ID tubing included.
*Integrated Fan Speed Control disabled and Pump Drive set to 80%
**Integrated Fan Speed Control active and Pump Drive set to 80%
T257P-20 | |
---|---|
Model # | T257P-20 |
Cooling Capacity (at 0 Delta T) | 210 watts (730 Btu/hr) |
Pump Pressure (max) | 1.5 bar (21.75 psi) |
Pump Max Flow ratet | 4.0 LPM |
Pump Typet | Variable Drive Centrifugal (Pump Drive Settable from 30% 100%) |
Temperature Stability | +/- 0.1°C |
Temperature Range | -5 to +45°C |
Communication | RS-232 & USB |
Heating Capability | Yes |
Input Voltage | 100-240 VAC 50/60 Hz |
Max Input Power | 600 watts |
Noise Level | 57 dBa* (52 dBa)** |
Dimensions | 12.2 x 7.125 x 13.4 inches |
Weight | 17 bs (7.7 kg) |
T257P Pump Curves
Process Flow (LPM)
T257P-20 Typical Thermal Capacity
DeltaT °C (Set Temp - Ambient Temp)
T257P-20 Measurements
Comfortable, Convenient, Portable DVT Prevention
Types of Recoveries
- Blood circulation
- Post-operative pain and swelling
- DVT risk
- Reduce wound healing time
Therapy Offered
- DVT prevention therapy
Other Features
- Single patient use
- Portable and convenient
Benefits And Features
DVT Prophylaxis
Reduces DVT/PE risk by enhancing blood circulation in post operative recoveries and prolonged stationary periods
Easy-To-Use
Simple application and easy to read display allows you to monitor pressure and treatment times
Extended Runtime
Rapid, rechargeable batteries can provide up to 9 hours of therapy between charges
Portable and Lightweight
Bilateral calf wraps are comfortable, quiet to operate, and function cord free, allowing for convenient treatment
No items found.
No items found.
Need Help with Your Evolution 2 or Accessories?
Watch instructional videos on our YouTube Channel or Contact Us for more information on our products and services.
Evolution 2 Resources
Select the document for view or download